Skip to the content

Riester Vital Signs Monitor RVS-100

SKU: EQMRVS1

Advanced vital signs monitor for pulse oximetry, blood pressure and temperature measurements.
Riester�s RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure and temperature measurements. The device has �Monitor�, �Spot-Check� and �Triage� profile options and a high-performance touchscreen.

The RVS - 100 can communicate through a wired or wireless connection to the hospital�s EMR, according to the HL7 standard. The highly flexible, modular design offers many configurations and settings to suit the needs of hospitals, clinics, and private practices, as well as long-term care settings.

Product Details

3 measurement modes (Monitor, Spot-check, Triage)
High-sensitivity 8� TFT colour touch screen with self-explanatory user interface and integrated help- function
Displays SYS, DIA, MAP, Pulse, Temp, Plethysmogram
Clinical grade NIBP* including averaging mode
Programmable NIBP averaging mode (2-5 readings)
Riester SpO2 as Standard. (Can be upgraded to Nellcor Oximax or Masimo(POA))
Predictive Thermometer (Filac 3000) RI.1960-RRBXE only Model
Connectivity with the EMR - follows the HL7 standard
LAN Connectivity as standard
Programmable alarms (audible, visible) with 3 priority levels
Supports nurse call RJ11 port
Available as wall, desk and floor model
Can be expanded to wall diagnostic station
Internal memory for 5,000 measurements
Lithium-ion battery with up to 17 hours ON time
Options

Thermal printer (internal)
Barcode reader
Mobile stand RI.13317 including basket for storage (cuffs, sensors, cables)
WiFi

Accessories supplied with monitor

NIBP extension tube
2 cuffs (adult & adult large incl. connectors)
SpO2 sensor adult
SpO2 extension cable
Extra Accessories on RI.1960-RRBXE

Oral temperature probe
Probe cover
?

Technical Data

Monitor

Power Supply: 100 � 240 V AC, 50/60 Hz

Battery:

Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh,
Charging time to a 100%: 6 hours,
Operating time approx. 11 hours (new and fully charged battery at 25�C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval))
Low battery indicator
Charging battery indicator
Dimensions Monitor: L x H x W: 303 x 230 x 110 mm (11.93 x 9.06 x 4.33 in)

Weight: 3.60 kg (7.94 lb) including temp module, printer

Dimensions Basket: L x H x W: 270 x 225 x 200 mm (10.63 x 8.86 x 7.88 in)

Alarm:

Visible LEDs (Yellow, Red, Blue, Green, Orange)
Audible Speaker
Gives audible alarm, QRS tone
Supports Pitch Tone and multi-level volume
Alarm tones meet the requirement of IEC 60601-1-8.
Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone.
Ports:

1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15V/1.2 A
Clinical-grade NIBP (non-invasive blood pressure)

Measuring method: automatic oscillometric

Measurement range:
Adult SYS 30 � 270 mmHg, DIA 10 � 220 mmHg, MAP 20 � 235 mmHg
Pediatric SYS 30 � 235 mmHg, DIA 10 � 220 mmHg, MAP 20 � 225 mmHg
Neonate SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg

Cuff pressure range: 0 � 280 mmHg

Resolution: 1 mmHg

Pressure accuracy:

Static �3 mmHg
Clinic �5 mmHg, standard deviation ? 8 mmHg
Pulse rate range: 40 � 240 bpm
Pulse rate accuracy: 1 bpm
Initial inflation pressure:

Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software)
Adult 297 � 3 mmHg, Pediatric 252 � 3 mmHg , Neonate 147 � 3 mmHg
Alarm range:

SYS 0 � 300 mmHg
DIA 0 � 300 mmHg
MAP 0 � 300 mmHg
Riester SpO2

Measurement range: 0 � 100%
Resolution: 1%
Accuracy: �2% (70 to 100%)
�3% (40% to 69%)
Unspecified (0% to 39%)
Alarm range: 0 � 100%
Average time: 4 sec, 8 sec, 16 sec
Pulse rate

Measurement range: 20 � 250 bpm
Resolution: 1 bpm
Accuracy: �1% or �1 bpm whichever is greater
Predictive thermometer for RI.1960-RRBXE

Oral ( Quick Mode )
non-fever temps: 3-5 seconds
fever temps: 8-10 seconds
Oral ( Standard Mode ): 6-10 seconds
Axillary Mode: 8-12 seconds
Rectal Mode: 10-14 seconds
Direct Mode (all sites): 60-120 seconds
Measurement accuracy: 35.5�C - 42�C (95.9�F � 107.6�F)
Direct Mode (all sites): �0.1�C (�0.2�F)
Standard Prediction Mode (all sites): �0.1�C (�0.2�F)
Quick Prediction Mode (oral only): �0.3�C (�0.5�F)